CVE-2025-66052
Command injection in Vivotek IP7137 cameras
Description
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
INFO
Published Date :
Jan. 9, 2026, 12:15 p.m.
Last Modified :
Jan. 9, 2026, 12:15 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2025-66052
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 4.0 | HIGH | 4bb8329e-dd38-46c1-aafb-9bf32bcb93c6 | ||||
| CVSS 4.0 | HIGH | [email protected] |
Solution
- Restrict administrative access to trusted networks.
- Isolate the vulnerable camera from the internet.
- Implement network segmentation.
- Consider device replacement.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2025-66052.
| URL | Resource |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2025-66052 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2025-66052
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2025-66052 vulnerability anywhere in the article.
-
cert.pl
Vulnerabilities in firmware of Vivotek IP7137 camera
Vulnerabilities in firmware of Vivotek IP7137 camera CVE ID CVE-2025-66049 Publication date 09 January 2026 Vendor Vivotek Product IP7137 Vulnerable versions 0200a Vulnerability type (CWE) Missing Aut ... Read more
The following table lists the changes that have been made to the
CVE-2025-66052 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by [email protected]
Jan. 09, 2026
Action Type Old Value New Value Added Tag unsupported-when-assigned Added Description Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-78 Added Reference https://cert.pl/posts/2026/01/CVE-2025-66049