Latest CVE Feed
-
5.0
MEDIUMCVE-2025-69416
In the plex.tv backend for Plex Media Server (PMS) through 2025-12-31, a non-server device token can retrieve other tokens (intended for unrelated access) via clients.plex.tv/devices.xml.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
6.5
MEDIUMCVE-2026-21634
A malicious actor with access to the adjacent network could overflow the UniFi Protect Application (Version 6.1.79 and earlier) discovery protocol causing it to restart. Affected Products: UniFi Protect Application (Version 6.1.79 and earlier). ... Read more
Affected Products : unifi_protect- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Denial of Service
-
7.5
HIGHCVE-2025-59467
A Cross-Site Scripting (XSS) vulnerability in the UCRM Argentina AFIP invoices Plugin (v1.2.0 and earlier) could allow privilege escalation if an Administrator is tricked into visiting a crafted malicious page. This plugin is disabled by default. Affe... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
5.4
MEDIUMCVE-2025-67315
Cross Site Request Forgery vulnerability in Employee Leave Management System v.2.1 allows a remote attacker to escalate privileges via the manage-employee.php component... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Request Forgery
-
5.3
MEDIUMCVE-2025-10933
An integer underflow vulnerability in the Silicon Labs Z-Wave Protocol Controller can lead to out of bounds memory reads.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Memory Corruption
-
7.2
HIGHCVE-2025-66376
Zimbra Collaboration (ZCS) 10 before 10.0.18 and 10.1 before 10.1.13 allows Classic UI stored XSS via Cascading Style Sheets (CSS) @import directives in an HTML e-mail message.... Read more
Affected Products : collaboration- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
6.5
MEDIUMCVE-2025-15450
A vulnerability was identified in sfturing hosp_order up to 627f426331da8086ce8fff2017d65b1ddef384f8. Affected by this vulnerability is the function findOrderHosNum of the file /ssm_pro/orderHos/. Such manipulation of the argument hospitalAddress/hospital... Read more
Affected Products : hosp_order- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
6.8
MEDIUMCVE-2025-12513
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges. This issue affects Infra Monitoring... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
9.2
CRITICALCVE-2026-21440
AdonisJS is a TypeScript-first web framework. A Path Traversal vulnerability in AdonisJS multipart file handling may allow a remote attacker to write arbitrary files to arbitrary locations on the server filesystem. This impacts @adonisjs/bodyparser throug... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Path Traversal
-
7.5
HIGHCVE-2025-67160
An issue in Vatilon v1.12.37-20240124 allows attackers to access sensitive directories and files via a directory traversal.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Path Traversal
-
7.5
HIGHCVE-2025-67158
An authentication bypass in the /cgi-bin/jvsweb.cgi endpoint of Revotech I6032W-FHW v1.0.0014 - 20210517 allows attackers to access sensitive information and escalate privileges via a crafted HTTP request.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
6.9
MEDIUMCVE-2025-34171
CasaOS versions up to and including 0.4.15 expose multiple unauthenticated endpoints that allow remote attackers to retrieve sensitive configuration files and system debug information. The /v1/users/image endpoint can be abused with a user-controlled path... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
-
5.3
MEDIUMCVE-2026-21635
An Improper Access Control could allow a malicious actor in Wi-Fi range to the EV Station Lite (v1.5.2 and earlier) to use WiFi AutoLink feature on a device that was only adopted via Ethernet.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
7.5
HIGHCVE-2026-21452
MessagePack for Java is a serializer implementation for Java. A denial-of-service vulnerability exists in versions prior to 0.9.11 when deserializing .msgpack files containing EXT32 objects with attacker-controlled payload lengths. While MessagePack-Java ... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Denial of Service
-
9.3
CRITICALCVE-2025-64119
A vulnerability in Nuvation Battery Management System allows Authentication Bypass.This issue affects Battery Management System: through 2.3.9.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
7.2
HIGHCVE-2025-5965
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Bac... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
6.5
MEDIUMCVE-2026-0597
A flaw has been found in Campcodes Supplier Management System 1.0. Affected by this issue is some unknown functionality of the file /retailer/edit_profile.php. This manipulation of the argument txtRetailerAddress causes sql injection. Remote exploitation ... Read more
Affected Products : supplier_management_system- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
9.4
CRITICALCVE-2025-64120
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
7.7
HIGHCVE-2025-5591
Kentico Xperience 13 is vulnerable to a stored cross-site scripting attack via a form component, allowing an attacker to hijack a victim user’s session and perform actions in their security context.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
7.2
HIGHCVE-2025-64122
Insufficiently Protected Credentials vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Signature Spoofing by Key Theft.This issue affects Multi-Stack Controller (MSC): through 2.5.1.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cryptography