Latest CVE Feed
-
7.7
HIGHCVE-2025-5591
Kentico Xperience 13 is vulnerable to a stored cross-site scripting attack via a form component, allowing an attacker to hijack a victim user’s session and perform actions in their security context.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
7.5
HIGHCVE-2026-21452
MessagePack for Java is a serializer implementation for Java. A denial-of-service vulnerability exists in versions prior to 0.9.11 when deserializing .msgpack files containing EXT32 objects with attacker-controlled payload lengths. While MessagePack-Java ... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Denial of Service
-
9.4
CRITICALCVE-2025-64123
Unintended Proxy or Intermediary vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Network Boundary Bridging.This issue affects Multi-Stack Controller (MSC): through and including release 2.5.1.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
5.1
MEDIUMCVE-2026-0587
A security flaw has been discovered in Xinhu Rainrock RockOA up to 2.7.1. Affected is an unknown function of the file rock_page_gong.php of the component Cover Image Handler. The manipulation of the argument fengmian results in cross site scripting. The a... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
7.2
HIGHCVE-2025-5965
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Bac... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
5.3
MEDIUMCVE-2025-12519
Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configu... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
9.8
CRITICALCVE-2025-15026
Missing Authentication for Critical Function vulnerability in Centreon Infra Monitoring centreon-awie (Awie import module) allows Accessing Functionality Not Properly Constrained by ACLs. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, ... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
6.5
MEDIUMCVE-2025-65328
Mega-Fence (webgate-lib.*) 25.1.914 and prior trusts the first value of the X-Forwarded-For (XFF) header as the client IP without validating a trusted proxy chain. An attacker can supply an arbitrary XFF value in a remote request to spoof the client IP, w... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
6.5
MEDIUMCVE-2026-0597
A flaw has been found in Campcodes Supplier Management System 1.0. Affected by this issue is some unknown functionality of the file /retailer/edit_profile.php. This manipulation of the argument txtRetailerAddress causes sql injection. Remote exploitation ... Read more
Affected Products : supplier_management_system- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
9.8
CRITICALCVE-2025-14346
WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration ... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
8.7
HIGHCVE-2025-64124
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): before 2.5.1.... Read more
Affected Products :- Published: Jan. 03, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
5.3
MEDIUMCVE-2026-21635
An Improper Access Control could allow a malicious actor in Wi-Fi range to the EV Station Lite (v1.5.2 and earlier) to use WiFi AutoLink feature on a device that was only adopted via Ethernet.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
6.9
MEDIUMCVE-2025-34171
CasaOS versions up to and including 0.4.15 expose multiple unauthenticated endpoints that allow remote attackers to retrieve sensitive configuration files and system debug information. The /v1/users/image endpoint can be abused with a user-controlled path... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
-
7.1
HIGHCVE-2025-52519
An issue was discovered in the Camera in Samsung Mobile Processor and Wearable Processor Exynos 1330, 1380, 1480, 2400, 1580, and 2500. Improper validation of user-space input in the issimian device driver leads to information disclosure and a denial of s... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
5.5
MEDIUMCVE-2026-21444
libtpms, a library that provides software emulation of a Trusted Platform Module, has a flaw in versions 0.10.0 and 0.10.1. The commonly used integration of libtpms with OpenSSL 3.x contained a vulnerability related to the returned IV (initialization vect... Read more
Affected Products : libtpms- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cryptography
-
10.0
CRITICALCVE-2025-64121
Authentication Bypass Using an Alternate Path or Channel vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Authentication Bypass.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
7.3
HIGHCVE-2025-3646
Petlibro Smart Pet Feeder Platform versions up to 1.7.31 contains an authorization bypass vulnerability that allows unauthorized users to add users as shared owners to any device by exploiting missing permission checks. Attackers can send requests to the ... Read more
Affected Products :- Published: Jan. 04, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
7.8
HIGHCVE-2025-57836
An issue was discovered in Samsung Magician 6.3.0 through 8.3.2 on Windows. The installer creates a temporary folder with weak permissions during installation, allowing a non-admin user to perform DLL hijacking and escalate privileges.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
8.6
HIGHCVE-2025-14124
The Team WordPress plugin before 5.0.11 does not properly sanitize and escape a parameter before using it in a SQL statement via an AJAX action available to unauthenticated users, leading to a SQL injection.... Read more
Affected Products : team_-_wordpress_team_members_showcase- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
7.1
HIGHCVE-2025-69415
In Plex Media Server (PMS) through 1.42.2.10156, ability to access /myplex/account with a device token is not properly aligned with whether the device is currently associated with an account.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication